Facilities / Empire Green Generation Follansbee Operations

Empire Green Generation Follansbee Operations

Verified Facility identity checked by an admin.

Facility info

FieldValueSource
EPA registered namesEMPIRE GREEN GENERATION EMPIRE DIVERSIFIED ENERGY LLCEPA ECHO
Address810 Koppers Road, Follansbee, Brooke County, WV 26037EPA ECHO
Coordinates40.34167, -80.60745EPA ECHO
OperatorEmpire Green Generation, LLC (Empire Diversified Energy family)Verified
EPA programsClean Air Act (CAA) Hazardous waste (RCRA) Greenhouse Gas Reporting (GHG)EPA ECHO
NAICS221114, 238910, 325194EPA ECHO
Active in ECHOYesEPA ECHO
EPA region3EPA ECHO
EPA registry IDs110071846508
110069398663
EPA ECHO
Facility typepyrolysisInferred from an agency recordReasoning: The WVDEP engineering evaluation says the modified facility consists mainly of two pyrolysis trains (300A and 300B), each rated at 35 short tons per day of plastic feedstock.WVDEP DAQ engineering evaluation, R13-3555B (2026-10-26) ↗Recorded in report 2026-11-01-sweep
StagePermittingInferred from an agency recordReasoning: The notice puts draft permit R13-3555B out for public comment on WVDEP's preliminary determination, so a state air permit is pending.WVDEP DAQ Air Quality Permit Notice: Empire Green Generation, LLC, draft R13-3555B, 801 Koppers Road, Follansbee ↗Recorded in report 2026-11-01-sweep
First report mention2026-09-10A scheduled AI sweep first mentioned this facility in this report.Recorded in report 2026-09-10-sweep
EPA ECHO 2 locations registered with EPA, one per record. Open in OpenStreetMap ↗

EPA values come from the EPA snapshot 20261101_090957 and are shown in place of anything an AI sweep reported for the same field. AI-found values were found in public sources by scheduled AI sweeps; the token opens where the value was found: the passage quoted from the source or the reasoning behind the value, the source, and the report that recorded it. Quotes are copied by the AI and not yet checked against their sources. Verified values were set or checked by an admin.

Published data

EPA data as of: ECHO Exporter as of 2026-11-01 · RCRA compliance (RCRAInfo) as of 2026-11-01 · Toxics Release Inventory reporting years 2020–2024 · RCRA Biennial Report cycles 2021, 2023 · e-Manifest exported 2026-10-25, shipments 2020–2021

Identity & operationsEPA ECHO, TRI, RCRA Biennial Report · as of 2026-11-01

EPA tracks this facility under 2 separate EPA records, registered in Clean Air Act, Hazardous waste (RCRA) and Greenhouse Gas Reporting.

Parent company (TRI)
Not reported to TRI
RCRA generator status
code N (2023 Biennial Report)
EPA facility records
2 registry IDs

Details

110071846508 · EMPIRE GREEN GENERATIONCAA

801 Koppers Road, Follansbee, WV 26037

Operational status
Active
County
—
EPA region
Region 3
NAICS industry code
221114
Overall compliance status
No Violation Identified
Receiving water
Not flagged as impaired
Penalties assessed
$0
EPA programs this record is registered in
ProgramProgram IDsPermit / classificationCompliance statusQuarters in non-complianceActions, formal / informal
Clean Air Act03000WV00021 ↗No Classification In ICISNo Violation Identified0 quarters—
110069398663 · EMPIRE DIVERSIFIED ENERGY LLCRCRA, GHG

810 Koppers Road, Follansbee, WV 26037

Operational status
Active
County
Brooke County
EPA region
Region 3
NAICS industry code
238910, 325194
Overall compliance status
Violation
Receiving water
Not flagged as impaired
Penalties assessed
$0
EPA programs this record is registered in
ProgramProgram IDsPermit / classificationCompliance statusQuarters in non-complianceActions, formal / informal
Hazardous waste (RCRA)WVD004336749 ↗OtherViolation7 quarters0 / 5
Greenhouse Gas ReportingECHO Air Pollutant Report ↗————

Releases & emissionsEPA Toxics Release Inventory (Form R)

Does not report to TRI.

    Off-site transfersEPA Toxics Release Inventory (Form R)

    No TRI off-site transfers reported.

      Hazardous wasteEPA RCRA Biennial Report, e-Manifest · Biennial Report 2021, 2023 · e-Manifest 2020–2021

      The facility generated 0 tons of hazardous waste in the 2023 Biennial Report, down from 740 tons in 2021. 137 hazardous waste manifests recorded 1,607,670 kg shipped from 2020 to 2021.

      Hazardous waste generated, by how it was managed

      • Incineration
      • Fuel Blending
      • Sludge Trtmnt / Stab / Encap
      • Category not recorded
      2021740 tons
      20230 tons

      Waste shipped off site under hazardous waste manifests

      • Hazardous
      • Other waste on the manifests
      939,045 kg
      2020
      668,625 kg
      2021

      Details

      Hazardous waste generated, by report cycle2 rows
      Report cycleGeneratedHow it was managed
      2021740 tonsIncineration: 728 tons
      Fuel Blending: 7.8 tons
      Sludge Trtmnt / Stab / Encap: 2.7 tons
      20230 tonsNot recorded
      Waste characteristics, 2023 cycle4 items
      Generator status
      code N
      Acutely hazardous waste
      No
      EPA priority chemical in waste
      No
      Waste by source code
      — what the codes mean
      Hazardous waste shipped off site, by stream and receiver14 rows
      Physical formHazardous waste codesReceiving facilityManagement methodCyclesShipped
      W409
      Organic solids
      K147 Listed waste from a specific industry source
      ARCWOOD ENVIRONMENTAL EAST LIVERPOOL INC
      1250 Saint George St, East Liverpool, OH, 43920-3400
      H040
      Incineration
      2021590 tons
      W504
      Inorganic sludges
      K035 Listed waste from a specific industry source
      ARCWOOD ENVIRONMENTAL EAST LIVERPOOL INC
      1250 Saint George St, East Liverpool, OH, 43920-3400
      H040
      Incineration
      202194.2 tons
      W409
      Organic solids
      D009 Toxicity characteristic: Mercury
      D019 Toxicity characteristic: Carbon tetrachloride
      D040 Toxicity characteristic: Trichloroethylene
      ARCWOOD ENVIRONMENTAL EAST LIVERPOOL INC
      1250 Saint George St, East Liverpool, OH, 43920-3400
      H040
      Incineration
      202128.1 tons
      W409
      Organic solids
      D008 Toxicity characteristic: Lead
      D009 Toxicity characteristic: Mercury
      D018 Toxicity characteristic: Benzene
      ARCWOOD ENVIRONMENTAL EAST LIVERPOOL INC
      1250 Saint George St, East Liverpool, OH, 43920-3400
      H040
      Incineration
      202115.3 tons
      W211
      Organic liquids
      D001 Ignitable
      REWORLD TRON CORP
      35850 Schneider Ct, Avon, OH, 44011
      H061
      Fuel Blending
      20216.3 tons
      W002
      Lab packs
      D008 Toxicity characteristic: Lead
      D009 Toxicity characteristic: Mercury
      D018 Toxicity characteristic: Benzene
      D024 Toxicity characteristic: m-Cresol
      D025 Toxicity characteristic: p-Cresol
      K147 Listed waste from a specific industry source
      MICHIGAN DISPOSAL WASTE TREATMENT PLANT
      49350 North I94 Service Drive, Belleville, MI, 48111
      H110
      Sludge Trtmnt / Stab / Encap
      20212.4 tons
      W219
      Organic liquids
      D001 Ignitable
      D002 Corrosive
      D018 Toxicity characteristic: Benzene
      D026 Toxicity characteristic: Cresol
      EQ DETROIT INC
      1923 Frederick St, Detroit, MI, 48211
      H14120211.7 tons
      W203
      Organic liquids
      D001 Ignitable
      U002 Toxic discarded chemical product
      U220 Toxic discarded chemical product
      U239 Toxic discarded chemical product
      REWORLD TRON CORP
      35850 Schneider Ct, Avon, OH, 44011
      H061
      Fuel Blending
      20211.4 tons
      W310
      Inorganic solids
      K035 Listed waste from a specific industry source
      MICHIGAN DISPOSAL WASTE TREATMENT PLANT
      49350 North I94 Service Drive, Belleville, MI, 48111
      H110
      Sludge Trtmnt / Stab / Encap
      20210.28 tons
      W219
      Organic liquids
      D001 Ignitable
      D002 Corrosive
      D018 Toxicity characteristic: Benzene
      D026 Toxicity characteristic: Cresol
      ROSS INCINERATION SERVICES INC
      36790 Giles Rd, Grafton, OH, 44044
      H040
      Incineration
      20210.23 tons
      W209
      Organic liquids
      D001 Ignitable
      D035 Toxicity characteristic: Methyl ethyl ketone
      D039 Toxicity characteristic: Tetrachloroethylene
      REWORLD TRON CORP
      35850 Schneider Ct, Avon, OH, 44011
      H061
      Fuel Blending
      20210.22 tons
      W001
      Lab packs
      D001 Ignitable
      D002 Corrosive
      D011 Toxicity characteristic: Silver
      D018 Toxicity characteristic: Benzene
      U002 Toxic discarded chemical product
      U058 Toxic discarded chemical product
      U154 Toxic discarded chemical product
      U220 Toxic discarded chemical product
      U239 Toxic discarded chemical product
      ROSS INCINERATION SERVICES INC
      36790 Giles Rd, Grafton, OH, 44044
      H040
      Incineration
      20210.12 tons
      W004
      Lab packs
      D001 Ignitable
      D002 Corrosive
      P002 Acutely hazardous discarded chemical product
      U080 Toxic discarded chemical product
      U404 Toxic discarded chemical product
      ROSS INCINERATION SERVICES INC
      36790 Giles Rd, Grafton, OH, 44044
      H040
      Incineration
      20210.11 tons
      W103
      Inorganic liquids
      D002 Corrosive
      ROSS INCINERATION SERVICES INC
      36790 Giles Rd, Grafton, OH, 44044
      H040
      Incineration
      20210.005 tons
      Hazardous waste manifests, by year shipped2 rows
      YearManifestsTotal shippedOf which hazardous
      202071 manifests939,045 kg938,948 kg
      202166 manifests668,625 kg668,625 kg
      • The Biennial Report is filed every two years; tons are US short tons.

      Compliance & enforcementEPA ECHO, RCRAInfo · status as of 2026-11-01 · RCRA records 1981–2026

      ECHO lists the facility as “Violation” at the snapshot. 45 hazardous waste violations on record since 1985, 2 still open. Last inspected 2021-08-11.

      Compliance quarter by quarter Each box is one quarter, oldest on the left, ending at the snapshot (2026-11-01): _ no violation identified V violation S significant violation
      110071846508CAA____________
      110069398663RCRAV_____VVVVVV

      Hazardous waste inspections per year

      • Found a violation
      • No violation found
      1981
      1985
      1990
      1995
      2000
      2005
      2010
      2015
      2020
      2026

      Details

      Compliance summary for each EPA record2 rows
      Registry IDCompliance statusSignificant non-complierFormal actionsInformal actionsPenaltiesInspectionsLast inspection
      110071846508No Violation IdentifiedNo0 actions0 actions$00 inspections—
      110069398663ViolationNo0 actions5 actions$00 inspections2021-08-11
      Hazardous waste inspections, by year37 rows
      YearFound a violationNo violation found
      20262 inspections0 inspections
      20251 inspection0 inspections
      20240 inspections1 inspection
      20233 inspections0 inspections
      20221 inspection0 inspections
      20211 inspection0 inspections
      20200 inspections2 inspections
      20180 inspections1 inspection
      20160 inspections2 inspections
      20141 inspection2 inspections
      20130 inspections2 inspections
      20111 inspection3 inspections
      20100 inspections3 inspections
      20090 inspections1 inspection
      20080 inspections1 inspection
      20070 inspections1 inspection
      20060 inspections1 inspection
      20050 inspections2 inspections
      20040 inspections5 inspections
      20030 inspections4 inspections
      20021 inspection2 inspections
      20011 inspection3 inspections
      19992 inspections3 inspections
      19982 inspections8 inspections
      19975 inspections1 inspection
      19964 inspections3 inspections
      19952 inspections0 inspections
      19933 inspections3 inspections
      19912 inspections2 inspections
      19901 inspection1 inspection
      19891 inspection0 inspections
      19883 inspections3 inspections
      19872 inspections2 inspections
      19867 inspections3 inspections
      19851 inspection3 inspections
      19830 inspections4 inspections
      19810 inspections2 inspections
      Hazardous waste violations45 rows, 2 open
      DeterminedRuleWhat it coversReturned to compliance
      2026-03-31279.CStandards for Used Oil: GeneratorsOpen
      2025-09-22262.AStandards Applicable to Generators of HW: GeneralOpen
      2023-06-22262.AStandards Applicable to Generators of HW: General2023-08-22
      2022-09-26XXSState Statutory or Regulatory requirements that are broader-in-scope than the federal RCRA requirements2024-01-10
      2022-05-12279.CStandards for Used Oil: Generators2023-02-24
      2021-08-11273.BStandards for Universal Waste Management: Standards for Small Quantity Handlers2021-09-16
      2014-08-22273.BStandards for Universal Waste Management: Standards for Small Quantity Handlers2014-08-29
      2011-09-20264.IStandards for Owners and Operators of HW TSDs: Use and Management of Containers2011-09-29
      2011-09-20273.CStandards for Universal Waste Management: Standards for Large Quantity Handlers2011-09-29
      2001-03-01262.AStandards Applicable to Generators of HW: General2002-02-28
      2001-03-01262.CStandards Applicable to Generators of HW: Pre-Transport Requirements Applicable to Small and Large Quantity Generators2002-02-28
      1999-05-20262.AStandards Applicable to Generators of HW: General1999-05-26
      1999-05-20262.BStandards Applicable to Generators of HW: Manifest Requirements Applicable to Small and Large Quantity Generators1999-07-02
      1998-11-10262.AStandards Applicable to Generators of HW: General1999-02-15
      1997-03-19262.AStandards Applicable to Generators of HW: General1998-11-10
      1996-11-25262.AStandards Applicable to Generators of HW: General1997-09-30
      1996-08-28262.AStandards Applicable to Generators of HW: General1998-11-10
      1995-06-12262.AStandards Applicable to Generators of HW: General1996-06-19
      1995-06-08262.CStandards Applicable to Generators of HW: Pre-Transport Requirements Applicable to Small and Large Quantity Generators1995-06-08
      1995-06-08262.AStandards Applicable to Generators of HW: General1995-06-12
      1993-02-23265.FInterim Status Standards for Owners and Operators of HW TSDs: Ground-Water Monitoring1993-07-27
      1993-01-22262.CStandards Applicable to Generators of HW: Pre-Transport Requirements Applicable to Small and Large Quantity Generators1993-07-01
      1993-01-22262.AStandards Applicable to Generators of HW: General1993-07-01
      1991-01-28264.AStandards for Owners and Operators of HW TSDs: General2000-01-01
      1991-01-28262.CStandards Applicable to Generators of HW: Pre-Transport Requirements Applicable to Small and Large Quantity Generators1991-09-12
      1991-01-28262.BStandards Applicable to Generators of HW: Manifest Requirements Applicable to Small and Large Quantity Generators1991-09-12
      1990-01-23262.CStandards Applicable to Generators of HW: Pre-Transport Requirements Applicable to Small and Large Quantity Generators1991-01-28
      1990-01-23262.AStandards Applicable to Generators of HW: General1991-01-28
      1989-06-15262.CStandards Applicable to Generators of HW: Pre-Transport Requirements Applicable to Small and Large Quantity Generators1991-01-28
      1989-06-15262.AStandards Applicable to Generators of HW: General1991-01-28
      1989-06-15262.CStandards Applicable to Generators of HW: Pre-Transport Requirements Applicable to Small and Large Quantity Generators1990-01-23
      1988-12-07264.AStandards for Owners and Operators of HW TSDs: General1989-02-17
      1988-10-28264.AStandards for Owners and Operators of HW TSDs: General1989-02-17
      1988-05-11264.AStandards for Owners and Operators of HW TSDs: General1999-05-26
      1987-07-13264.AStandards for Owners and Operators of HW TSDs: General1987-11-14
      1987-01-27264.AStandards for Owners and Operators of HW TSDs: General1987-01-27
      1986-12-22264.AStandards for Owners and Operators of HW TSDs: General1987-05-05
      1986-12-19264.AStandards for Owners and Operators of HW TSDs: General1987-05-05
      1986-11-17264.AStandards for Owners and Operators of HW TSDs: General1987-05-05
      1986-11-17264.AStandards for Owners and Operators of HW TSDs: General1987-05-05
      1986-11-17FEAViolation of a formal enforcement agreement or order. (3008(a) or 3013)1987-05-05
      1986-03-16264.AStandards for Owners and Operators of HW TSDs: General1986-03-03
      1986-03-04264.AStandards for Owners and Operators of HW TSDs: General1986-03-04
      1986-01-21265.FInterim Status Standards for Owners and Operators of HW TSDs: Ground-Water Monitoring1999-05-26
      1985-11-07264.AStandards for Owners and Operators of HW TSDs: General1990-01-23
      Enforcement actions31 rows
      DateType codeActionFinal penalty
      2026-07-23HQ120WRITTEN INFORMALNone
      2026-05-04HQ120WRITTEN INFORMALNone
      2025-10-28HQ120WRITTEN INFORMALNone
      2023-07-11HQ120WRITTEN INFORMALNone
      2022-12-13HQ120WRITTEN INFORMALNone
      2021-08-11HQ120WRITTEN INFORMALNone
      2014-08-22HQ120WRITTEN INFORMALNone
      2011-09-20HQ120WRITTEN INFORMALNone
      2001-05-31HQ210INITIAL 3008(A) COMPLIANCENone
      2001-04-16WV121REFERRED TO ENVIRONMENTAL ENFORCEMENTNone
      2001-03-01HQ120WRITTEN INFORMALNone
      2000-03-01HQ120WRITTEN INFORMALNone
      1998-11-10HQ120WRITTEN INFORMALNone
      1998-04-02HQ310FINAL 3008(A) COMPLIANCE ORDER$8,266
      1997-09-30HQ210INITIAL 3008(A) COMPLIANCENone
      1997-03-19HQ120WRITTEN INFORMALNone
      1996-08-28HQ120WRITTEN INFORMALNone
      1995-06-12WV121REFERRED TO ENVIRONMENTAL ENFORCEMENTNone
      1995-06-08HQ120WRITTEN INFORMALNone
      1993-02-23HQ120WRITTEN INFORMALNone
      1993-01-22HQ120WRITTEN INFORMALNone
      1991-07-01HQ210INITIAL 3008(A) COMPLIANCENone
      1990-03-21HQ310FINAL 3008(A) COMPLIANCE ORDER$30,000
      1990-03-14HQ120WRITTEN INFORMALNone
      1989-07-13HQ120WRITTEN INFORMALNone
      1989-01-18HQ120WRITTEN INFORMALNone
      1987-09-13HQ120WRITTEN INFORMALNone
      1987-07-02HQ210INITIAL 3008(A) COMPLIANCENone
      1987-04-14HQ120WRITTEN INFORMALNone
      1987-01-27HQ110VERBAL INFORMALNone
      1986-02-14HQ120WRITTEN INFORMALNone

        Source datasnapshot 2026-11-01

        Snapshot 20261101_090957, refreshed 2026-11-01. Each dataset is as current as EPA's own file:

        Figures can differ from EPA's live portals where EPA has updated its data since then. Each EPA record's Detailed Facility Report is linked under Identity & operations.

        Rolling updates

        Scheduled AI sweeps of public sources find the stage, deadlines, and sources below, and an AI writes the summary from them. They may not be comprehensive. Check the linked sources before relying on any of it. About the data

        Summary from the latest report mention, AI-written

        Stage Permitting Inferred from an agency recordReasoning: The notice puts draft permit R13-3555B out for public comment on WVDEP's preliminary determination, so a state air permit is pending.WVDEP DAQ Air Quality Permit Notice: Empire Green Generation, LLC, draft R13-3555B, 801 Koppers Road, Follansbee ↗Recorded in report 2026-11-01-sweep

        • WVDEP DAQ R13 application R13-3555B (Facility ID 009-00141), received 03/27/2026, permit writer Andrews, still on the open NSR list as of 2026-09-29 with Public Notice Date and Last Day to Comment blank. No draft permit, listserv notice, or Brooke County legal notice found.
        • Prior application 13-3555A withdrawn after an EPA Section 114 request. 2026 file includes a Part 241 non-hazardous secondary material determination (6-24-2026) and revised Technotherm engine calculations (Subpart JJJJ). Plastics pyrolysis at ~70 tons per day reported, not confirmed.
        • OGW lists it as 'Empire Follansbee Syngas Plant' (facility 7196 / project 7199), status On Hold, last edited 2026-06-27, noting the parent's bankruptcy filing 12/16/25. The active 2026 R13 application is not recorded there; share with EIP.
        • DRAFT PERMIT ON PUBLIC NOTICE: WVDEP DAQ proposes to issue R13-3555B (preliminary determination). NSR sheet: DAQ Public Notice Date 10/30/2026, Last Day to Comment 11/30/26. Notice text: Empire Green Generation, LLC proposes to 'modify a medical waste treatment facility into a chemical manufacturing facility' at 801 Koppers Road, Follansbee, Brooke County. No process words in the notice (Lexicon Rule 4 'chemical manufacturing facility' framing).
        • Notice emission changes (tpy): VOC +16.45, total HAPs +9.77; PM2.5 -4.92, PM10 -11.68, PM -19.13, NOx -2.23, CO -70.72, SO2 -38.93. 'Written comments must be received by the DAQ before 5:00 p.m. on Monday, November 30, 2026.' Comments to daqpubliccomments@wv.gov (subject 'Empire Comments') or Edward Andrews, P.E., WVDEP DAQ, 601 57th Street SE, Charleston WV 25304, (304) 926-0499 ext. 41244. A public meeting only if significant interest is expressed in writing.
        • Engineering evaluation dated 2026-10-26 (Andrews; read by a research pass): an 'advanced chemical recycling manufacturing facility'; two pyrolysis trains (300A, 300B) at about 2,917 lb/hr each (~35 tons/day each); feedstock 85% polyethylene and polypropylene, 0% PVC; syngas burned in four 429 bhp engines; pyrolysis oil tank 55TK01 and loading rack; carbon black; no regenerative thermal oxidizer. Finds CAA section 129 and Subparts CCCC/DDDD do not apply on a 40 CFR Part 241 non-waste analysis; Subpart AAAA and Subpart EEEE (OSWI) not discussed.
        • The WVDEP up-to-90-day statutory review clock runs from the preliminary determination, separate from the comment window. OGW still lists the project as On Hold; this action not recorded there.

        From report 2026-11-01-sweep

        Open deadlines

        Sources (8) AI-found

        Date foundKindTitleNoteReport
        2026-11-01agencyWVDEP DAQ Air Quality Permit Notice: Empire Green Generation, LLC, draft R13-3555B, 801 Koppers Road, FollansbeeRead via r.jina.ai. 'modify a medical waste treatment facility into a chemical manufacturing facility'; VOC +16.45 tpy, HAPs +9.77 tpy; comments by 5:00 p.m. 2026-11-30.2026-11-01-sweep
        2026-11-01agencyWVDEP DAQ engineering evaluation, R13-3555B (2026-10-26)Two pyrolysis trains ~35 tons/day each; 85% PE/PP feedstock; syngas engines; pyrolysis oil and carbon black; Part 241 non-waste basis for section 129 non-applicability. Read by a research pass.2026-11-01-sweep
        2026-11-01agencyWVDEP DAQ NSR applications sheet: R13-3555B notice date 10/30/2026, last day to comment 11/30/2678 data rows read 2026-11-01 via r.jina.ai; first time the Empire notice fields are filled.2026-11-01-sweep
        2026-09-29otherOil & Gas Watch: Empire Follansbee Syngas Plant (facility 7196)On Hold; parent bankruptcy 12/16/25; 2026 R13 application not recorded.2026-09-29-sweep
        2026-09-29agencyWVDEP DAQ NSR applications list (published Google Sheet)Underlying table of the NSR page; R13-3555B row with notice fields blank as of 2026-09-29.2026-09-29-sweep
        2026-09-10agencyEmpire Green Generation - 40 CFR Part 241 determination, 6-24-26 (PDF)Empty body to tools; needs a human download.2026-09-10-sweep
        2026-09-10agencyEmpire Green Generation R13 application 13-3555B (PDF)Empty body to tools; needs a human download.2026-09-10-sweep
        2026-09-10agencyWVDEP DAQ NSR permit applications pageLists 13-3555B with Last Day to Comment blank.2026-09-10-sweep